EATON FAZ-C1.5/1-NA-SP Standard Current Limiting Supplementary Protector, 277/480 VAC, 1.5 A, 10 to 14 kA Interrupt, 1 Poles, 5-10X/Thermal Magnetic Trip

Short Description

EATON offers a full range of DIN-rail miniature circuit breakers up to 40 A current rating for feeder and branch circuit protection. breakers comply with the latest national and international standards including UL 489. Two levels of circuit protection available, one for medium inrush startup currents to provide protection for small transformers, pilot devices and more and one with a magnetic range to allow for higher inrush levels during startup usually seen with motors.

EATON Supplementary Protector, Standard Current Limiting, Series: FAZ, 277/480 VAC, 1.5 A, 50/60 Hz Frequency, 10 to 14 kA Interrupt, 5-10X/Thermal Magnetic Trip, 1 Pole, Handle Actuator, 18 to 6 AWG Wire, IP20 Enclosure, DIN Rail Mounting, -40 to 75 deg C, 0.7 in L x 2.97 in W x 4.13 in H Dimensions, Nylon
MFG #: FAZ-C1.5/1-NA-SP

EECO #: CHFAZC1.51NASP

Brand: Eaton
Attributes
Features
Documents
Product Information
Attributes
UNSPSC
39121603
Material
Nylon
Trip Type
5-10X/Thermal Magnetic
Wire Size
18 to 6
Application
Circuit Protection, Convenience Receptacle Circuits, Motor Control Circuits, Load Circuits Leaving The Equipment, HACR Equipment, PLC I/O Points, Computers, Power Supplies, Control Instrumentation, Relays, UPS, Power Conditioners, Industrial, Generation, Renewable Energy, Alternative Energy, Conventional Energy, Datacenters - IT Space, CI and Hyper Converged and Marine Vessels Applications
Mounting Type
DIN Rail
Enclosure Type
IP20
Voltage Rating
277/480
Frequency Rating
50/60
Temperature Rating
-40 to 75
Type
Standard Current Limiting
Series
FAZ
Dimensions
0.7 in L x 2.97 in W x 4.13 in H
Actuator Type
Handle
Amperage Rating
1.5
Features
  • Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit
  • Thermal magnetic over current protection
  • Three levels of short circuit protection, categorized by B, C and D curves
  • Trip-free design breaker can not be defeated by holding the handle in the On position
  • A color coded red/green indicator provides immediate visual indication of device status (green for Off, red for On) and isolation function
  • Power to the circuit breakers can be fed from the line or load side
  • Easy installation on DIN rail
  • To save installation time, bus connectors and feeder terminal facilitate mounting and wiring of multiple miniature circuit breaker arrays in control panel assemblies
everwhere
EATON FAZ-C1.5/1-NA-SP Standard Current Limiting Supplementary Protector, 277/480 VAC, 1.5 A, 10 to 14 kA Interrupt, 1 Poles, 5-10X/Thermal Magnetic Trip