Bussmann Fusetron™ FRS-R-450 Current Limiting Renewable Time Delay Fuse, 450 A, 600 VAC/300 VDC, 200 kA Interrupt, RK5 Class, Cartridge Body

Short Description

Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500% of rated current (8 seconds for 1/10-30A sizes).

Bussmann Fusetron™ Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 450 A, 600 VAC/300 VDC, 200 kA Interrupt, Class: RK5, 10 s at 500% Response, Blade Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 2.88 in Dia x 13.38 in L Body Size
MFG #: FRS-R-450

EECO #: BUFRSR450

Brand: Bussmann
UPC #: 051712508544
Attributes
Features
Documents
Product Information
Attributes
Class
RK5
UNSPSC
39121606
Material
Fiberglass
Application
Combination Starters, Machinery Disconnects, Motor Control Centers and Power Panelboard Applications, Safety and Security Systems
Mounting Type
Holder
Response Time
10 s at 500%
Terminal Type
Blade
Voltage Rating
600 VAC/300 VDC
Type
Current Limiting Renewable
Series
FRS-R
Amperage Rating
450
Features
  • Provides motor overload, ground fault and short circuit protection
  • When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full-load amps to give maximum over current protection
  • The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides a good deg of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
  • Gives motor running back-up protection to motors without extra cost
  • Helps protect motors against burnout from overloads and single phasing when sized properly
  • Simplifies and improves blackout prevention (selective co-ordination ratios)
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
everwhere

Products Related To This Item

More Options Like This
Bussmann Fusetron™ FRS-R-450 Current Limiting Renewable Time Delay Fuse, 450 A, 600 VAC/300 VDC, 200 kA Interrupt, RK5 Class, Cartridge Body