Bussmann Fusetron™ FRS-R-200 Current Limiting Time Delay Renewable Fuse, 200 A, 600 VAC/300 VDC, 200/20 kAIC Interrupt, RK5 Class, Cartridge Body

Short Description

600 VAC, 300 VDC, 200 A, Blade Terminal, Class RK5, 10 Sec Time Delay, UL Power Fuse

Bussmann Fusetron™ Renewable Fuse, Current Limiting Time Delay, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 200 A, 600 VAC/300 VDC, 200/20 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Blade End Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 1.61 in Dia x 9.63 in L Body Size

MFG #: FRS-R-200

EECO #: BUFRSR200

Brand: Bussmann
UPC #: 051712508483
Attributes
Features
Documents
Product Information
Attributes
Class
RK5
UNSPSC
39121606
Approval
UL 248-12, CSA C22.2, CE
Material
Fiberglass
Application
Industrial Facilities and Factories, Safety and Security Systems, Combination Starters, Machinery Disconnects, Motor Control Centers and Power Panelboard Applications
Mounting Type
Holder
Response Time
10 s at 500%
Terminal Type
Blade End
Current Rating
200 Amp
Voltage Rating
600 VAC/300 VDC
Characteristics
10 Second Time Delay (at 500 Percent Rated Load), Dual Element, Non-Indicating
Interrupting Rating
200 Kiloamp Symmetrical (AC), 20 Kiloamp (DC)
Type
Current Limiting Time Delay
Series
FRS-R
Diameter
1.61 Inch
Amperage Rating
200
Features
  • Provides motor overload, ground fault and short circuit protection
  • When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection
  • The time delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides a good degree of short circuit protection (greater current limitation) to help protect downstream components from high fault currents
  • Gives motor running back-up protection to motors without extra costs
  • Helps protect motors against burnout from overloads and 1 ph when sized properly
  • Simplifies and improves blackout prevention (selective co-ordination ratios)
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection