Edison ECSR200 ECSR Current Limiting Time Delay Fuse, 200 A, 600 V, 200 kAIC Interrupt, Class: RK5, Cartridge Body

Short Description

Edisons UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.

Edison, ECSR200, Fuse, Current Limiting Time Delay, Series: ECSR, Non-Indicating, Rejection, 200 A, 600 V, 200 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Blade End Terminal, Holder Mounting, Cartridge Body, Dual Element, Fiberglass, 1.61 in Dia x 9.63 in L Body
MFG #: ECSR200

EECO #: BUECSR200

Brand: Edison
UPC #: 782634508489
Attributes
Features
Documents
Product Information
Attributes
Class
RK5
UNSPSC
39121606
Material
Fiberglass
Application
Industrial Facilities and Factories, Safety and Security Systems, AC Power Distribution System Mains, Feeders, Branch Circuits, Motor, Motor Branch Circuits, Transformers and Other Inductive Loads Applications
Mounting Type
Holder
Response Time
10 s at 500%
Terminal Type
Blade End
Voltage Rating
600
Type
Current Limiting Time Delay
Series
ECSR
Amperage Rating
200
Features
  • Provides motor overload, ground fault and short circuit protection
  • When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection
  • The time delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides a higher degree of short circuit protection (greater current limitation) in circuits in which surge currents or temporary overloads occur
  • Gives motor running back-up protection to motors without extra costs
  • Helps protect motors against burnout from 1 ph on 3 ph systems
  • Simplifies and improves blackout prevention (selective co-ordination ratios)
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
  • Superior overload and cycling capabilities
  • True dual element construction allows sizing of 125% FLA for motor backup protection
  • Current limiting provides component short circuit protection
  • For all general purpose applications including lighting, heating and other non-inductive loads
  • Tin plated copper brass terminal and zinc plated steel screws
everwhere