Appleton® UNILETS® EYS8 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 3 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated

Short Description

These Appleton® sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another. They prevent pressure piling within the conduit system and contain any explosion that occurs. These models in the EYS series provide a close turning radius and can be used for sealing vertical or horizontal conduit runs.

Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EYS, 3 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Gray, Triple Coated, 8-1/2 in L x 4-1/4 in W
MFG #: EYS8

EECO #: APEYS8

Brand: Appleton
UPC #: 781381621083
Attributes
Features
Documents
Product Information
Attributes
Color
Gray
Finish
Triple Coated
UNSPSC
39121311
Material
Grayloy-Iron
Application
For prevent passage of gases, vapors or flames from one portion of conduit system to another
Size
3
Type
Dust-Ignitionproof Explosionproof Raintight
Series
EYS
Warranty
Limited
Dimensions
8-1/2 in L x 4-1/4 in W
Suitable For Use With
IMC/Threaded Rigid Metallic Conduit
Features
  • Smooth, rounded integral bushing in each hub to protect conductor insulation
  • Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
  • Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
  • Large opening for damming and filling
  • Restrict any explosion to the sealed off enclosure
  • Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
  • Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
  • Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
  • Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
  • Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
  • Tapered FNPT connection
  • 25% fill vertical and horizontal conduit sealing fittings for close turning radius
  • Chromate/epoxy powder coated/zinc electroplated finish