Appleton® UNILETS® EYD36 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting With Removable Male Nipple, 1 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated

Short Description

Ensure safety and reliability with the Appleton® UNILETS® EYD36 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting. Designed for 1-inch IMC/Threaded Rigid Metallic Conduit, this durable fitting features a removable male nipple and a robust triple-coated Grayloy-Iron construction, making it ideal for demanding environments.Enhanced by AI

Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EYD, 1 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Gray, Triple Coated, 4.31 in L x 2.19 in W

MFG #: EYD36

EECO #: APEYD36

Brand: Appleton
UPC #: 781381620895
Attributes
Features
Documents
Product Information
Attributes
Color
Gray
Finish
Triple Coated
UNSPSC
39121311
Material
Grayloy-Iron
Application
For prevent passage of gases, vapors or flames from one portion of conduit system to another
Size
1
Type
Dust-Ignitionproof Explosionproof Raintight
Series
EYD
Warranty
Limited
Dimensions
4.31 in L x 2.19 in W
Suitable For Use With
IMC/Threaded Rigid Metallic Conduit
Features
  • Smooth, rounded integral bushing in each hub to protect conductor insulation
  • Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
  • Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
  • Restrict any explosion to the sealed off enclosure
  • Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
  • Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
  • Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
  • Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
  • Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
  • Tapered MNPT X tapered FNPT connection
  • 25% fill vertical conduit drain sealing fittings
  • Chromate/epoxy powder coated/zinc electroplated finish
everwhere
Appleton® UNILETS® EYD36 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting With Removable Male Nipple, 1 in, For Use With IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Triple Coated